Standard Screenings
Commercial Products
REMEC D&S commercial filters are temperature stabilized, stabilization baked, and 100% RF tested. Sample testing is performed for humidity, shock, and vibration. Custom specifications can be addressed.
Military Products
Unless otherwise specified by the customer, products will be supplied for military applications with special attention given to temperature range and other environmental requirements.
Standard screening levels are shown in the table below:
| Test |
Specification and Method |
| Internal Visual |
MIL STD-202 Method 107 (-65 C to +125 C 14 cycles, 60 minute soak, 5 minute ramp) |
| Hermeticity |
Gross leak per MIL-STD-883, Method 1014, Condition C or per MIL-STD-202 Method 112, Condition D; Fine leak, if required by specification, per MIL-STD-883, Method 1014, Condition A or MIL-STD-202, Method 112, Condition C |
| Final Electrical |
Per applicable Acceptance Test Procedure (ATP) |
| External Visual |
Per REMEC D&S internal quality assurance procedures including weight and physical dimensions check |
Space Products